Photoelectric Beam Sensor Outdoor TAKEX PB-IN-100AT(R)(E)
Photoelectric Beam Sensor Outdoor TAKEX PB-IN-100AT(R)(E)
- Four Frequency Selection: 4 separate choices of frequency avoids cross-talk in stacked or long linear installations.
- Dual Response time system
+ Two individual response times are provided for separate adjustment of AND/OR gates.
+ This enables detection of intruders, but minimizes false alarms.
- Beam Transmission strength selection: 2 levels of beam transmission strength which can be set to suit the protection distance.
- Auto-Gain Lock: Optimal sensitivity gain is automatically set at any coverage distance up to the maximum protection distance. Auto-Gain lock is easily confirmed by sound check.
- Easy Beam Alignment:
+ Audible signal for alignment [Utility model] ... An alignment tone aids in quick set-up beams. The tone becomes maximum at peak of beam level.
+ Beam selector ... Upper and lower beam alignment can be adjusted without using a shading plate.
+ Sensitivity attenuation LED ... Lights when beam level is attenuated, which shows low sensitivity.
+ Monitor jack output.
- Programmed AGC: Sensitivity is automatically increased in bad weather to contend with fog, heavy rain, frost or snow.
- Environmental module built-in: Environmental trouble signal is sent when beam reception level is reduced below an acceptable level.
- Protection Against Frost/Dew: As a special hood is attached on sensor cover, beam protection continues without interruption even when the cover is screened by frost or dew.
Thông số kỹ thuật
Detection system | Near infrared beam interruption system (TR,-RE 4 beams simultaneous interruption or upper 2 beams interruption or lower 2 beams interruption) |
Infrared beam | Double modulation pulsed beam by LED |
Protection distance | Outdoor 100m (330') or less |
Max. arrival distance | Tenfold 1000m (3300') |
Response time | Dual response time system 35-500msec. (AND gated) 100,200,300,500msec.(OR gated) |
Power supply | 12V to 30V DC(non-polarity) |
Current consumption | 85mA or less at protection(Max. 120mA or less) |
Alarm output | Dry contact relay output 1c Reset:Interruption time+off-delay(approx. 1.5 sec.) Contact capacity:30V AC/DC, 1A or less |
Environmental output | Dry contact relay:1c Contact operation:Output when weather condition gets worse Contact capacity:30V AC/DC, 1A or less |
Tamper output | Dry contact relay:1b Contact operation:Output when transmitter or receiver cover is detached Contact capacity:30V AC/DC, 0.1A or less |
Alarm LED | Red LED(receiver)lights when an alarm is initiated |
Sensitivity attenuation LED | Red LED(receiver)lights when beam reception is attenuated |
Functions | Modulated beam frequency selection,Tone indicator, Environmental module, Beam power selection, Beam selector, Programmed AGC. Auto-gain lock function, Monitor jack. |
Beam adjustment | Horizontal: +/-90°, Vertical: +/-10° |
Ambient temperature range | -35C to + 66C (-31F to + 151F) |
Mounting position | Outdoor |
Wiring | Terminals |
Weight | Transmitter:1200g(42 oz) Receiver :1300g(45.5oz) |
Appearance | PC resin(wine red) |